POL-X West, Inc.
Engineering Services for the
Transportation & Amusement Ride Industries
Jasper Tramway Terminal and Tower Finite Element Analysis
The
upgrade of the Jasper Tramway begun in 2000 by Garaventa AG required the verification
of the structure of the upper terminal and tower to insure the loads of the new
system did not cause the structures to be overstressed. POL-X West was asked to provide a finite
element analysis (FEA) of the structures and identify any areas which may need
to be reinforced due to the change in loading.
POL-X West used ALGOR finite element software to
perform this analysis. The tower and
upper terminal were modeled using beam elements for the structural members and
plate
elements for built-up components such as saddles,
and for enclosure surfaces such as walls and roofs. Localized loads were modeled as point forces while snow, wind,
and distributed cable loads were modeled as pressure loads on the appropriate
surfaces. In this way, several load
cases were created which accurately simulated the various combinations of loads
which would be expected by the structure.